Digital Insulation Resistanc Tester:
• Complies with IEC/EN 61010-1 1000V CAT III 600 V CAT IV• Secondary injection molding case• SMT application
***Basic Functions:
• Insulation Measurement Range : 0.01 MΩ ~ 2 GΩ. • Insulation Test Voltages : 50V/100V/250V/ 500V/1000 V .• Insulation Source Voltage: + 20 %, - 0 %.• Insulation Short-Circuit Test Current : 1 .5mA nominal.
• DCV measurement: 600mV/6V/60V/600V/1000V ±(0.5%rdg) • ACV TRMS measurement: 600mV/6V/60V/600V/750V ±(1.5%rdg) • DC Current measurement: 60mA/400mA ±(1.0%rdg)• AC Current measurement: 60mA/400mA ±(1.5%rdg)• Resistance measurement:600Ω/6kΩ/60kΩ/600kΩ±(1.2%rdg);6MΩ/60MΩ±(2.0%rdg)• Capacitance measurement: 6nF/60nF/600nF/6uF/60uF/600uF/6mF/60mF±(3.0%rdg)• Temperature measurement: -30°C~ 1300°C ±(1.0%rdg).• Frequency measurement: 660Hz/6.6kHz/66kHz ±(1.5%rdg+5digits).
***Special Functions: • Auto/Manual Range• True RMS for AC Voltage and Current• MAX/MIN/Average/Relative value measurement, record 100 sets of data.• Battery voltage detector/Low battery indication/ Auto Power off• Auto display outer voltage with PI (Polarization Index) and DAR (Dielectric Absorption Rate)• Overload protective voltage : 600V.• Standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.• Insulation Auto Discharge : Discharge time <1 second for C = 1 μF or less.• Insulation Live Circuit Detection : Inhibit test if terminal voltage > 20 V prior to initialization of test.• Insulation Maximum Capacitive Load: Operable with up to 1 μF load.• Max display: 6600 counts with backlight
***Environment Characteristics:
• Operating Temperature: 0°C ~ 40 °C
• Storage Temperature : -40 °C ~ 60 °C. • Relative Humidity: 40%~75%(40%~60% when insulation test >1 GΩ)***General Characteristics:
• Power: 1.5V AAA* 4
• Product color: Yellow and Black
• Product size : 205*102*58mm
• Product Net Weight: 390g
• Standard Accessories: Test Leads, Clips , battery, User Manual, Gift Box
• Standard Individual Packing: Gift Box
• Standard Quantity per Carton: 10 pcs
• Standard Carton Meas: 58*46*22cm (0.0587CBM per standard carton)
• Standard Carton Gross Weight: 13.0kg
***Applications:
• Apply for measuring and maintining in Communications, metallurgy, petroleum, manufacturing, defence, chemical, power and other industries field.
• Apply for measuring and maintining the on-site of power equipment and power supply
***WARRANTY: one year
------------------------------------------------------
Technical Specifications:
1. Insulation Resistance Measurement:
OutputVoltage | Display Range | Resolution | Resistance Accuracy |
50V(0~20%) | 0~5MΩ | 0.01 MΩ | ±(3%+5Lsd) |
5~50MΩ | 0.1 MΩ | ||
100V(0~20%) | 0~5MΩ | 0.01 MΩ | ±(3%+5 Lsd ) |
5~50MΩ | 0.1 MΩ | ||
50~100MΩ | 1MΩ | ||
250V(0~20%) | 0~25MΩ | 0.1 MΩ | ±(3%+5 Lsd ) |
25~250MΩ | 1MΩ | ||
500V(0~20%) | 0~50MΩ | 0.1 MΩ | ±(3%+5 Lsd ) |
50~500MΩ | 1MΩ | ||
1000V(0~20%) | 0~5MΩ | 0.1 MΩ | ±(3%+5 Lsd ) |
5~500MΩ | 1 MΩ | ||
0.5G~2.0GΩ | 0.1GΩ | ±(5%+5 Lsd ) |